| AIRBUS INDUSTRIES 31000 TOULOUSE FRANCE |
Hydraulic test units. | Detected the wear of a thrust bearing. The user decided to equipe all other units. |
| ARKEMA 73130 LA CHAMBRE FRANCE |
Bearings of furnace blower. | User continued using bearing mounted with unsufficient clearance. After 5 months of applying grease at each MECASON alarm (every 3 days), the user discovered the over tightened condition. With the re-adjustment of the bearings clearance and one last grease application, the measured levels stablised at the normal noise level . After more than a year, bearing is still in service. |
| SOCIETE D'EXPLOITATION DES
TELEPHERIQUES TARENTAISE MAURIENNE 73440 VAL-THORENS FRANCE |
Electric motors and reducers for ski station lifts. | All new installations are equipped. Detected needs in lubricant quantities much higher than stated by the machine manufacturers (grease applications at 400 hr intervals instead of every 2000 hrs.) |
| COMPAGNIE FRANCO-TUNISIENNE DES PETROLES Champ de Sidi-El-Iteyem SFAX TUNISIA |
Monitoring of valve slap on Creusot-Loire 1 MW piston compressors. | MECASON shut down the compressor after the aspiration of condensat into the cylinder. Two other compressors have been equipped (first part of 1997). |
| COMPAGNIE GENERALE DES EAUX 06000 NICE FRANCE |
Vertical centrifugal pumps. | A bearing having shown signs of weakness in the past was shown to be stable. Discovery of different lubrication needs from one machine to another. Three years later; still no interventions ! |
| ELECTRICITE DE FRANCE EDF Centrale de Passy 74190 PASSY FRANCE |
THydro-electric turbine gear boxes and generators. | Detected malfunction of automatic greaser only 4 months after installation of MECASON. |
| TOTAL (Production) 64170 LACQ FRANCE |
Centrifigal pumps. | Excellent correlation with IRD Inc measurements. |
| RHODIA 38800 PONT DE CLAIX FRANCE |
Horizontal centrifugal separator bearings. | Entry of solvents into the bearing housing occurs regularly. MECASON sounds the alarm to allow operators to purge with grease and adjust the nitrogen barrier pressure. Unit still without intervention after repeated incidents. |